{"id":1327,"date":"2025-04-09T15:54:51","date_gmt":"2025-04-09T15:54:51","guid":{"rendered":"https:\/\/wiraelectrical.com\/nl\/?p=1327"},"modified":"2025-04-09T15:54:51","modified_gmt":"2025-04-09T15:54:51","slug":"gebalanceerde-wye-delta-verbinding","status":"publish","type":"post","link":"https:\/\/wiraelectrical.com\/nl\/gebalanceerde-wye-delta-verbinding\/","title":{"rendered":"Gebalanceerde Wye-Delta-verbinding"},"content":{"rendered":"\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Vergeleken met de gebalanceerde ster-ster-verbinding zullen we de meest praktische van de vier configuraties leren kennen: de gebalanceerde ster-driehoekverbinding.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Zoals de naam al aangeeft, is de gebalanceerde ster-driehoekverbinding een <\/span><a href=\"https:\/\/wiraelectrical.com\/nl\/wat-is-een-elektrisch-circuit\/\"><span style=\"font-weight: 400;\">elektrisch circuit<\/span><\/a><span style=\"font-weight: 400;\"> waarin een gebalanceerde ster-bron een gebalanceerde driehoek-belasting voedt.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Dit is de tweede van de vier configuraties:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400; text-align: justify;\" aria-level=\"1\"><a href=\"https:\/\/wiraelectrical.com\/nl\/gebalanceerde-wye-wye-verbinding\/\"><span style=\"font-weight: 400;\">Gebalanceerde ster-ster-verbinding<\/span><\/a><\/li>\n<li style=\"font-weight: 400; text-align: justify;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Gebalanceerde ster-delta verbinding<\/span><\/li>\n<li style=\"font-weight: 400; text-align: justify;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Gebalanceerde delta-delta verbinding<\/span><\/li>\n<li style=\"font-weight: 400; text-align: justify;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Gebalanceerde delta-ster-verbinding<\/span><\/li>\n<\/ul>\n\n\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Gebalanceerde Wye-Delta-verbinding<\/strong><\/h2>\n\n\n\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Waarom hebben we een gebalanceerde bron en een gebalanceerde belasting nodig?<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Stel dat we een gebalanceerde driefasenspanning en een gebalanceerde drie fasen belasting hebben. Omdat er geen verschil in grootte is, is de elektrische stroom ook in harmonie met de spanning. Er is geen verschil in hun <\/span><a href=\"https:\/\/wiraelectrical.com\/nl\/sinusoidale-golfvorm\/\"><span style=\"font-weight: 400;\">sinusvormige golfvormen<\/span><\/a><span style=\"font-weight: 400;\"> in een gebalanceerd driefasensysteem.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Een gebalanceerd driefasensysteem heeft een gebalanceerd driefasen vermogen.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Als de spanning en stroom in een circuit in harmonie zijn, zal de arbeidsfactor dicht bij \u00e9\u00e9n liggen. Dit betekent dat ons circuit een goede vermogensoverdracht effici\u00ebntie heeft en onze machine een langere levensduur heeft.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Wat gebeurt er als we een ongebalanceerd drie fasen circuit hebben? De meest praktische oplossing is een <\/span><a href=\"https:\/\/wiraelectrical.com\/nl\/vermogensfactor-correctie\/\"><span style=\"font-weight: 400;\">vermogensfactor correctie<\/span><\/a><span style=\"font-weight: 400;\">, maar hiervoor is een geavanceerde kennis van <\/span><a href=\"https:\/\/wiraelectrical.com\/nl\/eenvoudig-wisselstroom-circuit\/\"><span style=\"font-weight: 400;\">wisselstroom circuits<\/span><\/a><span style=\"font-weight: 400;\"> vereist.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Onthoud het volgende:<\/span><\/p>\n<blockquote>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Een gebalanceerde driefasen-ster-driehoekschakeling is een driefasen bron met een gebalanceerde ster-geschakelde bron en een gebalanceerde driehoek-geschakelde belasting.<\/span><\/p>\n<\/blockquote>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Laten we direct naar de circuit analyse en het voorbeeld gaan.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Bekijk het onderstaande gebalanceerde ster-driehoek bedradingsschema, met links een <\/span><a href=\"https:\/\/wiraelectrical.com\/nl\/gebalanceerde-driefasenspanning\/\"><span style=\"font-weight: 400;\">gebalanceerde driefasenspanning<\/span><\/a><span style=\"font-weight: 400;\"> bron in sterconfiguratie en een gebalanceerde drie fasen belasting in driehoek configuratie.<\/span><\/p>\n<p style=\"text-align: justify;\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-1328\" src=\"http:\/\/wiraelectrical.com\/nl\/wp-content\/uploads\/sites\/4\/2025\/04\/gebalanceerde-ster-delta-verbinding-1.jpg\" alt=\"gebalanceerde ster-delta verbinding 1\" width=\"1373\" height=\"815\" srcset=\"https:\/\/wiraelectrical.com\/nl\/wp-content\/uploads\/sites\/4\/2025\/04\/gebalanceerde-ster-delta-verbinding-1.jpg 1373w, https:\/\/wiraelectrical.com\/nl\/wp-content\/uploads\/sites\/4\/2025\/04\/gebalanceerde-ster-delta-verbinding-1-300x178.jpg 300w, https:\/\/wiraelectrical.com\/nl\/wp-content\/uploads\/sites\/4\/2025\/04\/gebalanceerde-ster-delta-verbinding-1-1024x608.jpg 1024w, https:\/\/wiraelectrical.com\/nl\/wp-content\/uploads\/sites\/4\/2025\/04\/gebalanceerde-ster-delta-verbinding-1-768x456.jpg 768w\" sizes=\"auto, (max-width: 1373px) 100vw, 1373px\" \/><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Uit onze bespreking van de gebalanceerde wye-wye-verbinding verwijderen we:<\/span><\/p>\n<ul style=\"text-align: justify;\">\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">ZS als de interne impedantie van de fasewikkeling van de generator als onze bron.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Z<sub>l<\/sub> als de impedantie van de lijn die een fase van de bron verbindt met een fase van de belasting. Dit is de impedantie van onze geleiders.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Z<sub>n<\/sub> is de impedantie van de neutrale lijn die het neutrale punt van de voeding en de belasting verbindt.<\/span><\/li>\n<\/ul>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Omdat deze drie verwaarloosbaar zijn, aangezien hun waarden minuscuul zijn in vergelijking met de belastingimpedantie.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">We gebruiken Z<sub>\u0394<\/sub> als onze equivalente impedanties om de totale impedantie in driehoek geschakeld belastingen weer te geven.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Vergeleken met een ster-driehoeksverbinding, waarbij er een neutrale lijn is tussen de voeding en de belasting, is er geen neutrale lijn in een ster-driehoek verbindingsschema.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Veronderstel dat we een positieve sequentie hebben (abc-sequentie), dan zijn de fasespanningen<\/span><\/p>\n<p style=\"text-align: justify;\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-1334\" src=\"http:\/\/wiraelectrical.com\/nl\/wp-content\/uploads\/sites\/4\/2025\/04\/1-2.gif\" alt=\"\" width=\"304\" height=\"83\" \/><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">De lijnspanningen zijn<\/span><\/p>\n<p style=\"text-align: justify;\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-1335\" src=\"http:\/\/wiraelectrical.com\/nl\/wp-content\/uploads\/sites\/4\/2025\/04\/2-2.gif\" alt=\"\" width=\"374\" height=\"244\" \/><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Hieruit blijkt dat de spanning over de belastingsimpedanties van dit systeem gelijk is aan de netspanningen die deze verbinding gebruiken.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Uit deze netspanningen kunnen we de fasestroom afleiden.<\/span><\/p>\n<p style=\"text-align: justify;\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-1336\" src=\"http:\/\/wiraelectrical.com\/nl\/wp-content\/uploads\/sites\/4\/2025\/04\/3-2.gif\" alt=\"\" width=\"103\" height=\"157\" \/><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Deze stromen hebben dezelfde grootte, maar zijn 120\u00b0 uit fase.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Een andere manier om deze fasestromen te bepalen, is door de spanningswet van Kirchhoff toe te passen. We kunnen bijvoorbeeld KVL toepassen rond lus aABbna.<\/span><\/p>\n<p style=\"text-align: justify;\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-1329\" src=\"http:\/\/wiraelectrical.com\/nl\/wp-content\/uploads\/sites\/4\/2025\/04\/gebalanceerde-ster-delta-verbinding-2.jpg\" alt=\"gebalanceerde ster-delta verbinding 2\" width=\"1373\" height=\"815\" srcset=\"https:\/\/wiraelectrical.com\/nl\/wp-content\/uploads\/sites\/4\/2025\/04\/gebalanceerde-ster-delta-verbinding-2.jpg 1373w, https:\/\/wiraelectrical.com\/nl\/wp-content\/uploads\/sites\/4\/2025\/04\/gebalanceerde-ster-delta-verbinding-2-300x178.jpg 300w, https:\/\/wiraelectrical.com\/nl\/wp-content\/uploads\/sites\/4\/2025\/04\/gebalanceerde-ster-delta-verbinding-2-1024x608.jpg 1024w, https:\/\/wiraelectrical.com\/nl\/wp-content\/uploads\/sites\/4\/2025\/04\/gebalanceerde-ster-delta-verbinding-2-768x456.jpg 768w\" sizes=\"auto, (max-width: 1373px) 100vw, 1373px\" \/><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">En de fasestroom is<\/span><\/p>\n<p style=\"text-align: justify;\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-1337\" src=\"http:\/\/wiraelectrical.com\/nl\/wp-content\/uploads\/sites\/4\/2025\/04\/4-2.gif\" alt=\"\" width=\"281\" height=\"77\" \/><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Hetzelfde geldt voor de vorige fasestroom methode. Deze is eenvoudiger uit te voeren, omdat we de basis-KVL op het circuit kunnen toepassen.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">De lijnstromen worden verkregen uit de fasestromen door de stroomwet van Kirchoff toe te passen op knooppunten A, B en C.<\/span><\/p>\n<p style=\"text-align: justify;\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-1330\" src=\"http:\/\/wiraelectrical.com\/nl\/wp-content\/uploads\/sites\/4\/2025\/04\/gebalanceerde-ster-delta-verbinding-3.jpg\" alt=\"gebalanceerde ster-delta verbinding 3\" width=\"1373\" height=\"815\" srcset=\"https:\/\/wiraelectrical.com\/nl\/wp-content\/uploads\/sites\/4\/2025\/04\/gebalanceerde-ster-delta-verbinding-3.jpg 1373w, https:\/\/wiraelectrical.com\/nl\/wp-content\/uploads\/sites\/4\/2025\/04\/gebalanceerde-ster-delta-verbinding-3-300x178.jpg 300w, https:\/\/wiraelectrical.com\/nl\/wp-content\/uploads\/sites\/4\/2025\/04\/gebalanceerde-ster-delta-verbinding-3-1024x608.jpg 1024w, https:\/\/wiraelectrical.com\/nl\/wp-content\/uploads\/sites\/4\/2025\/04\/gebalanceerde-ster-delta-verbinding-3-768x456.jpg 768w\" sizes=\"auto, (max-width: 1373px) 100vw, 1373px\" \/><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Dus,<\/span><\/p>\n<p style=\"text-align: justify;\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-1338\" src=\"http:\/\/wiraelectrical.com\/nl\/wp-content\/uploads\/sites\/4\/2025\/04\/5-2.gif\" alt=\"\" width=\"142\" height=\"82\" \/><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Omdat I<sub>CA<\/sub> = I<sub>AB<\/sub>\u2220\u2212240\u00b0,<\/span><\/p>\n<p style=\"text-align: justify;\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-1339\" src=\"http:\/\/wiraelectrical.com\/nl\/wp-content\/uploads\/sites\/4\/2025\/04\/6-2.gif\" alt=\"\" width=\"536\" height=\"58\" \/><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">waaruit blijkt dat de grootte IL van de lijnstroom \u221a3 maal de grootte Ip van de fasestroom is, of<\/span><\/p>\n<p style=\"text-align: justify;\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-1340\" src=\"http:\/\/wiraelectrical.com\/nl\/wp-content\/uploads\/sites\/4\/2025\/04\/7-1.gif\" alt=\"\" width=\"100\" height=\"23\" \/><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Waar<\/span><\/p>\n<p style=\"text-align: justify;\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-1341\" src=\"http:\/\/wiraelectrical.com\/nl\/wp-content\/uploads\/sites\/4\/2025\/04\/8-1.gif\" alt=\"\" width=\"194\" height=\"23\" \/><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">En<\/span><\/p>\n<p style=\"text-align: justify;\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-1342\" src=\"http:\/\/wiraelectrical.com\/nl\/wp-content\/uploads\/sites\/4\/2025\/04\/9-1.gif\" alt=\"\" width=\"245\" height=\"23\" \/><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Bovendien lopen de lijnstromen 30\u00b0 achter op de corresponderende fasestromen, uitgaande van de positieve volgorde.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Hieronder ziet u een fasordiagram dat de relatie tussen de fase- en lijnstromen illustreert.<\/span><\/p>\n<p style=\"text-align: justify;\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-1331\" src=\"http:\/\/wiraelectrical.com\/nl\/wp-content\/uploads\/sites\/4\/2025\/04\/gebalanceerde-ster-delta-verbinding-4.jpg\" alt=\"gebalanceerde ster-delta verbinding 4\" width=\"1373\" height=\"815\" srcset=\"https:\/\/wiraelectrical.com\/nl\/wp-content\/uploads\/sites\/4\/2025\/04\/gebalanceerde-ster-delta-verbinding-4.jpg 1373w, https:\/\/wiraelectrical.com\/nl\/wp-content\/uploads\/sites\/4\/2025\/04\/gebalanceerde-ster-delta-verbinding-4-300x178.jpg 300w, https:\/\/wiraelectrical.com\/nl\/wp-content\/uploads\/sites\/4\/2025\/04\/gebalanceerde-ster-delta-verbinding-4-1024x608.jpg 1024w, https:\/\/wiraelectrical.com\/nl\/wp-content\/uploads\/sites\/4\/2025\/04\/gebalanceerde-ster-delta-verbinding-4-768x456.jpg 768w\" sizes=\"auto, (max-width: 1373px) 100vw, 1373px\" \/><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Een alternatieve manier om de ster-driehoekschakeling te analyseren is door de in driehoek geschakelde belasting te transformeren naar een equivalente in ster geschakelde belasting.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Met behulp van de formule voor de delta-ster-transformatie:<\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-1343\" src=\"http:\/\/wiraelectrical.com\/nl\/wp-content\/uploads\/sites\/4\/2025\/04\/10-1.gif\" alt=\"\" width=\"87\" height=\"45\" \/><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Na deze transformatie hebben we nu een ster-ster-systeem, zoals in de gebalanceerde ster-ster-verbinding.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">We kunnen het driefase ster-driehoek systeem in de bovenstaande illustratie omzetten naar een eenfase-equivalent circuit zoals hieronder getekend. Dit stelt ons in staat om alleen de lijnstromen te berekenen.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Waarom moeten we de driehoekbelasting omzetten naar sterbelasting?<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Omdat we eenvoudig een deel van de ster-ster-verbinding kunnen omzetten naar een eenfasecircuit.<\/span><\/p>\n<p style=\"text-align: justify;\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-1332\" src=\"http:\/\/wiraelectrical.com\/nl\/wp-content\/uploads\/sites\/4\/2025\/04\/gebalanceerde-ster-delta-verbinding-5.jpg\" alt=\"gebalanceerde ster-delta verbinding 5\" width=\"1373\" height=\"815\" srcset=\"https:\/\/wiraelectrical.com\/nl\/wp-content\/uploads\/sites\/4\/2025\/04\/gebalanceerde-ster-delta-verbinding-5.jpg 1373w, https:\/\/wiraelectrical.com\/nl\/wp-content\/uploads\/sites\/4\/2025\/04\/gebalanceerde-ster-delta-verbinding-5-300x178.jpg 300w, https:\/\/wiraelectrical.com\/nl\/wp-content\/uploads\/sites\/4\/2025\/04\/gebalanceerde-ster-delta-verbinding-5-1024x608.jpg 1024w, https:\/\/wiraelectrical.com\/nl\/wp-content\/uploads\/sites\/4\/2025\/04\/gebalanceerde-ster-delta-verbinding-5-768x456.jpg 768w\" sizes=\"auto, (max-width: 1373px) 100vw, 1373px\" \/><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">De fasestromen worden verkregen met behulp van bovenstaande lijnstroom vergelijking, waarbij gebruik wordt gemaakt van het feit dat elke fasestroom 30\u00b0 voorloopt op de overeenkomstige lijnstroom.<\/span><\/p>\n<p style=\"text-align: justify;\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-1333\" src=\"http:\/\/wiraelectrical.com\/nl\/wp-content\/uploads\/sites\/4\/2025\/04\/gebalanceerde-ster-delta-verbinding-6.jpg\" alt=\"gebalanceerde ster-delta verbinding 6\" width=\"1373\" height=\"815\" srcset=\"https:\/\/wiraelectrical.com\/nl\/wp-content\/uploads\/sites\/4\/2025\/04\/gebalanceerde-ster-delta-verbinding-6.jpg 1373w, https:\/\/wiraelectrical.com\/nl\/wp-content\/uploads\/sites\/4\/2025\/04\/gebalanceerde-ster-delta-verbinding-6-300x178.jpg 300w, https:\/\/wiraelectrical.com\/nl\/wp-content\/uploads\/sites\/4\/2025\/04\/gebalanceerde-ster-delta-verbinding-6-1024x608.jpg 1024w, https:\/\/wiraelectrical.com\/nl\/wp-content\/uploads\/sites\/4\/2025\/04\/gebalanceerde-ster-delta-verbinding-6-768x456.jpg 768w\" sizes=\"auto, (max-width: 1373px) 100vw, 1373px\" \/><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Voorbeeld van een gebalanceerde ster-driehoekverbinding<\/strong><\/h2>\n\n\n\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Een gebalanceerd <\/span><a href=\"https:\/\/wiraelectrical.com\/nl\/drie-fase-wisselstroom-circuits\/\"><span style=\"font-weight: 400;\">driefasen wisselstroom circuit<\/span><\/a><span style=\"font-weight: 400;\"> met een gebalanceerde ster-driehoek configuratie.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Een gebalanceerde abc-sequentie ster-geschakelde bron met V<sub>an<\/sub> = 100\u222010\u00b0 V is aangesloten op een driehoek-geschakelde gebalanceerde belasting (8 + j4) \u03a9 per fase.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">We moeten de fase- en netstromen berekenen.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Antwoord:<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">We kunnen dit probleem op twee manieren oplossen.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Methode 1<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">De belastingsimpedantie is<\/span><\/p>\n<p style=\"text-align: justify;\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-1344\" src=\"http:\/\/wiraelectrical.com\/nl\/wp-content\/uploads\/sites\/4\/2025\/04\/11-1.gif\" alt=\"\" width=\"280\" height=\"21\" \/><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Als de fasespanning V<sub>an<\/sub> = 100\u222010\u00b0, dan is de netspanning<\/span><\/p>\n<p style=\"text-align: justify;\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-1345\" src=\"http:\/\/wiraelectrical.com\/nl\/wp-content\/uploads\/sites\/4\/2025\/04\/12-1.gif\" alt=\"\" width=\"426\" height=\"55\" \/><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">De fasestromen zijn<\/span><\/p>\n<p style=\"text-align: justify;\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-1346\" src=\"http:\/\/wiraelectrical.com\/nl\/wp-content\/uploads\/sites\/4\/2025\/04\/13-1.gif\" alt=\"\" width=\"425\" height=\"109\" \/><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">De lijnstromen zijn<\/span><\/p>\n<p style=\"text-align: justify;\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-1347\" src=\"http:\/\/wiraelectrical.com\/nl\/wp-content\/uploads\/sites\/4\/2025\/04\/14.gif\" alt=\"\" width=\"444\" height=\"119\" \/><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Methode 2<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Als alternatief kunt u eenfase analyse gebruiken,<\/span><\/p>\n<p style=\"text-align: justify;\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-1348\" src=\"http:\/\/wiraelectrical.com\/nl\/wp-content\/uploads\/sites\/4\/2025\/04\/15.gif\" alt=\"\" width=\"254\" height=\"76\" \/><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Zoals hierboven. Andere lijnstromen worden verkregen met behulp van de abc-fasevolgorde.<\/span><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Veelgestelde vragen<\/strong><\/h2>\n\n\n\n<div data-schema-only=\"false\" class=\"wp-block-aioseo-faq\"><h3 class=\"aioseo-faq-block-question\">Hoe weet ik of mijn 3-fase schakeling in driehoek of ster is?<\/h3><div class=\"aioseo-faq-block-answer\">\n<p class=\"wp-block-paragraph\">De driehoek configuratie heeft een driefasen bron of -belasting die in een driehoek is aangesloten, waarbij de kop is verbonden met een andere staart, enzovoort.<\/p>\n<\/div><\/div>\n\n\n\n<div data-schema-only=\"false\" class=\"wp-block-aioseo-faq\"><h3 class=\"aioseo-faq-block-question\">Is de driehoekverbinding gebalanceerd?<\/h3><div class=\"aioseo-faq-block-answer\">\n<p class=\"wp-block-paragraph\">Een driefasen schakeling in driehoek heeft geen nuldraad zoals in een sterschakeling en de fasespanning is gelijk aan de netspanning. De netstroom is wortel drie (\u221a3) keer de fasestroom.<\/p>\n<\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Vergeleken met de gebalanceerde ster-ster-verbinding zullen we de meest praktische van de vier configuraties leren kennen: de gebalanceerde ster-driehoekverbinding. Zoals de naam al aangeeft, is de gebalanceerde ster-driehoekverbinding een elektrisch circuit waarin een gebalanceerde ster-bron een gebalanceerde driehoek-belasting voedt. Dit is de tweede van de vier configuraties: Gebalanceerde ster-ster-verbinding Gebalanceerde ster-delta verbinding Gebalanceerde delta-delta verbinding &#8230; <a title=\"Gebalanceerde Wye-Delta-verbinding\" class=\"read-more\" href=\"https:\/\/wiraelectrical.com\/nl\/gebalanceerde-wye-delta-verbinding\/\" aria-label=\"Read more about Gebalanceerde Wye-Delta-verbinding\">Read more<\/a><\/p>\n","protected":false},"author":1,"featured_media":1349,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[33],"tags":[],"class_list":["post-1327","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-wisselstroomcircuit"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/wiraelectrical.com\/nl\/wp-json\/wp\/v2\/posts\/1327","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/wiraelectrical.com\/nl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/wiraelectrical.com\/nl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/wiraelectrical.com\/nl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/wiraelectrical.com\/nl\/wp-json\/wp\/v2\/comments?post=1327"}],"version-history":[{"count":1,"href":"https:\/\/wiraelectrical.com\/nl\/wp-json\/wp\/v2\/posts\/1327\/revisions"}],"predecessor-version":[{"id":1350,"href":"https:\/\/wiraelectrical.com\/nl\/wp-json\/wp\/v2\/posts\/1327\/revisions\/1350"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/wiraelectrical.com\/nl\/wp-json\/wp\/v2\/media\/1349"}],"wp:attachment":[{"href":"https:\/\/wiraelectrical.com\/nl\/wp-json\/wp\/v2\/media?parent=1327"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/wiraelectrical.com\/nl\/wp-json\/wp\/v2\/categories?post=1327"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/wiraelectrical.com\/nl\/wp-json\/wp\/v2\/tags?post=1327"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}